
- #York model ycal xhiller discharge sensor full#
- #York model ycal xhiller discharge sensor registration#
The ARPA Zone/Open Membership Discussion Forums. RULES for AOP - Owner Assistance and Contractors. Ask Our Pros-Owner Assistance - NO DIY advice will be given. Questions About Becoming A Professional Member? Step Inside. Quick Navigation Tech to Tech Chat - Commercial Top paying JCI to come out would also be a good idea.well, it should be a good idea, anyway. Having actual logged data would be helpful. if you plugged up the heat exchanger, this may be the root cause of the potential low flow issue. Removing the strainers is a very, very bad idea and may be part of the problem. especially, if you have a high ambient condition.īecause they are occurring on both circuits, it is likely that you have a problem with the chilled fluid flow rate changing too quickly or running too low of a flow rate. The "MP/HPCO" is probably due to overheating the compressors at such a low suction pressure. When these fail, the chiller can not control the EEV's any longer and shutdown. The "Sensor Failure" diagnostic is due to having the Suction Temperature sensor and/or Suction Pressure transducer are "out of range" which is < -12C and < 1.01 barg. Max Water Flow: 40 liters/sec 46.17 kPa pressure drop (approximate) Min Water Flow: 7.5 liters/sec 6.35 kPa pressure drop (approximate) YLAA, size 350, 50 Hz, Brazed Plate Heat Exchanger, 34% PG it is likely that you have "50".ģ4% 4F FP means you are running propylene glycol. I am not familiar with a voltage code of "52" in your model number. #York model ycal xhiller discharge sensor registration#
If you have any problems with the registration process or your account login, please contact support.
We suggest not registering using an AT&T, BellSouth, AOL or Yahoo email address. Gain access to our free AOP (Ask a Professional) Section to get real answers for your questions.Īll this and much more is available to you absolutely free when you register for an account, so join our community today today!.Post photos, respond to polls and access other special features.Participate in over 40 different forums and search/browse from nearly 3 million posts.As a registered Guest you will be able to:
#York model ycal xhiller discharge sensor full#
To gain full access to our forums you must register for a free account. You are currently viewing as a NON-REGISTERED guest which gives you limited access to view discussions Welcome to, a non-DIY site and the ultimate Source for HVAC Information & Knowledge Sharing for the industry professional! Here you can join over 150,000 HVAC Professionals & enthusiasts from around the world discussing all things related to HVAC/R.By continuing to use the website, you consent to our use of cookies. To learn about our use of cookies and how you can manage your cookie settings, please see our Cookie Policy. We use cookies to improve your website experience.